Skip to main content

FLOODED DEEP CYCLE BATTERY

8 NS 23P

Series 5000 Warranty 5 Years
Volts 8 Design SLI
Cells 4 Plates/Cell 23
Terminal Type Flag RR
Charge
Charge Voltage Range 2.45-2.5 V/cell @ 25°C (77°F)
Float Voltage Range 2.25 V/cell @ 25°C (77°F)
Self-Discharge Rate 5%-10% per month at 25°C (77°F)
Capacity
Cold Crank Amps (CCA) 0°F / -18°C 1559
Marine Crank Amps (MCA) 32°F / 0°C 1949
Reserve Capacity (RC @ 25A) 1123 Minutes
Reserve Capacity (RC @ 75A) 374 Minutes
Capacity Affect by Temperature 40°C
(104°F)
25°C
(77°F)
0°C
(32°F)
-15°C
(5°F)
105% 100% 75% 50%
Hour Rate Capacity / AMP Hour Current / AMPs
@ 100 Hour Rate 538 AH 5.38 A
@ 72 Hour Rate 524 AH 7.28 A
@ 50 Hour Rate 505 AH 10.11 A
@ 20 Hour Rate 468 AH 23.40 A
@ 15 Hour Rate 440 AH 29.33 A
@ 10 Hour Rate 421 AH 42.12 A
@ 8 Hour Rate 402 AH 50.31 A
@ 5 Hour Rate 374 AH 74.88 A
@ 1 Hour Rate 220 AH 219.96 A

Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F).
Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250.

Specifications
Weight 109.5 kg 241.5 lbs
Length 718 mm 28.25"
Width 210 mm 8.25"
Height Incl. Term. 464 mm 18.25"
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components.
Electrolyte Reserve 143 mm 5.63"
Container (Inner) Polypropylene
Cover (Inner) Polypropylene - heat sealed to inner container
Container (Outer) High Density Polyethylene
Cover (Outer) High Density Polyethylene snap fit to outer container
Handles Molded
  • Plastics are UL94 HB (UL94-V2 available)
  • Plastics are impact copolymer rated to ASTM D256, D5420
  • Vented design with integral flame arrestor vent caps

Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration

Rev.#5 | August 2024