FLOODED DEEP CYCLE BATTERY |
12 CS 13P |
|
|
| Series | FLA SERIES 5000 | Warranty | 5 Years |
|---|---|---|---|
| Volts | 12 | Design | SPEC |
| Cells | 6 | Plates/Cell | 13 |
| Terminal Type | Flag L | ||
| Included Hardware | S/S Hex Cap Screw, Nut, Lock & Flat Washer | ||
| Size & Thread | 5/16"-18 | ||
| Cables | 19" 4/0 interconnect cables *RE incl. | ||
| Charge | Discharge | |
|---|---|
| Charge Voltage Range | 14.7-15 V/cell @ 25°C (77°F) |
| Recommended Charge Current | 45 A |
| Maximum Charge Current | 70 A |
| Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
| Capacity | |
|---|---|
| Cold Crank Amps (CCA) 0°F / -18°C | 1045 |
| Marine Crank Amps (MCA) 32°F / 0°C | 1306 |
| Reserve Capacity (RC @ 25A) | 1068 Minutes |
| Reserve Capacity (RC @ 75A) | 356 Minutes |
| Capacity Affect by Temperature | 40°C (104°F) |
25°C (77°F) |
0°C (32°F) |
-15°C (5°F) |
|---|---|---|---|---|
| 105% | 100% | 75% | 50% |
| Hour Rate | Capacity / AMP Hour | Current / AMPs |
|---|---|---|
| @ 100 Hour Rate | 574 AH | 5.74 A |
| @ 72 Hour Rate | 543 AH | 7.54 A |
| @ 50 Hour Rate | 514 AH | 10.28 A |
| @ 20 Hour Rate | 445 AH | 20.25 A |
| @ 15 Hour Rate | 414 AH | 27.59 A |
| @ 10 Hour Rate | 396 AH | 39.61 A |
| @ 8 Hour Rate | 383 AH | 47.84 A |
| @ 5 Hour Rate | 356 AH | 71.20 A |
| @ 1 Hour Rate | 200 AH | 200.25 A |
| Specifications | |||
|---|---|---|---|
| Weight | 136 kg | 300 lbs | |
| Length | 492 mm | 19.38" | |
| Width | 273 mm | 10.75" | |
| Height Incl. Term. | 425 mm | 16.75" | |
| Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. | |||
| Electrolyte Reserve | 8.6 mm | 3.38" | |
|---|---|---|---|
| Handles | Integrated Top Mount | ||
|
|||
Cycle Life vs. Depth of Discharge
Voltage vs. Depth of Discharge
Detailed Illustration